• 尊龙凯时

    CYB1800 series differential pressure transmitter
    2021年1月18日
    CYB1500 series clamp-type pressure transmitter
    2021年1月22日

    CYB3700 series flange pressure transmitters


    1 Introduction

    CYB3700 series flange pressure transmitters carefully select high-reliability silicon piezoresistance, ceramic capacitors, sapphire, sputtering film pressure sensors, etc. as the core components according to the application characteristics of different industries. After temperature compensation, digital circuit correction and signal conditioning, Output standard industrial signals. Each type of product has undergone careful design, component screening, process verification and curing, cyclic loading and aging, environmental simulation testing and other processes to ensure that each product is stable and reliable.

     

    2 Features

    ◆on-site display, multiple output signal options

    ◆high stability, low drift

    ◆explosion-proof, IP66 protection

    ◆applicable to harsh environments such as pollution, humidity, flammability and explosion

     

    3 Main uses

    With its excellent accuracy and reliability, CYB3700 series flange pressure transmitters are widely used in many types of pressure measurement, especially in coal mine, oil field, chemical industry, civil explosion, environmental protection, medicine, water affairs, shipping and other industries. Brand pressure transmitters have been widely recognized by customers.

     

    4 Technical index

    range

    MPa

    -0.1MPa…0kPa~10kPa…10MPa

    pressure form

    G、A

    accuracy level

    0.1(customized)

    0.25

    0.5

    nonlinearity (FS%)

    ≤0.1

    ≤0.2

    ≤0.4

    hysteresis, repeatability (FS%)

    ≤0.05

    ≤0.05

    ≤0.1

    zero point and sensitivity temperature drift (%FS/℃)

    ≤0.015

    ≤0.03

    ≤0.05

    long-term stability (%FS/year)

    ≤0.1

    ≤0.2

    ≤0.5

    operating Voltage (VDC)

    +10~+30( The calibration value is +24)

    on site display

    4-bit LED or LCD

    output signal

    4mA~20mA( Can superimpose HART protocol )、RS485( Can output 4mA~20mA signal at the same time )、

    0~10V( Output range can be customized )、I2C

    compensation temperature (℃)

    0~+50(≤200kPa),-10~60(>200kPa)

    operating temperature(℃)

    -30~+60

    overload capacity (%)

     ≤200

    load resistance (Ω)

    (4mA~20mA)

    R=(U-12)/0.02-RD

    Among them: U is the power supply voltage

    RD is the internal resistance of the cable

    response time (10%~90%)ms

    ≤1

    measuring medium

    Fluid compatible with 304, 316L or ceramic

    diaphragm material

    316L、 ceramics

    shell material

    304、 Aluminum alloy

    interface

    304, 316L optional

    explosion-proof grade

    Intrinsically safe :Ex d IIC T5 Gb

    protection level

    IP65

     

    5 Transmitter size

    CYB3700 1.jpg

     

    6 Electrical connections

    6.1 Cable direct outle

    CYB3700 2.jpg CYB3700 3.jpg

    6.2 Industrial terminal

    CYB3700 4.jpg

     

    7 Order guide

    7.1 Model characteristics and appearance

    model

    features

    pattern

    CYB3702

    1、Welded transmitter meets the hygienic requirements of the pharmaceutical and food industries;

    2、Optional range: -0.1MPa…0kPa~10kPa…10MPa;

     

    CYB3700 5.jpg

                                                                                     CYB03703

    1、Ceramic capacitor flange type pressure transmitter

    2、Measuring medium temperature -40℃~80℃;

    3、Suitable for non-corrosive medium to ceramics and stainless steel;

    4、The pressure sensitive film is exposed, suitable for viscous media.

    CYB3700 6.jpg

    CYB3704

    1、Anti-corrosion type can be customized;

    2、Customized on-site display;

    CYB3700 7.jpg

    7.2 Selection guide

    CYB37X3X4

    Flange pressure transmitter

     

    Range

    Measuring range: -0.1MPa…0MPa~0.01MPa…10MPa

    xxn

    The unit is kPa, the first two digits xx value is multiplied by the n square of 10, and n is the third digit value.

     

     

    Code

    name

    Pressure form

    G

    Gauge

    A

    Absolute

    D

    Differential pressure

    S

    Sealed gauge pressure type

     

     

    Code

    name

    Supply voltage

    U1

    24VDC

    U2

    12VDC

    U5

    Other power supply methods

     

     

     

    Code

    name

    output signal

    E1

    4mA~20mADC

    V3

    0VDC~10VDC

    V5

    Other voltage output

    R4

    RS485 Communication Interface

    H

    HART® Protocol communication

    I2C Protocol communication

     

     

     

    Mechanical interface

    G1

    M20×1.5

    Other( Direct label )

     

     

     

    code

    Additional functions

    M1

    4-digit LCD digital display header

    M2

    4-digit LED digital display header

    i

    Intrinsically safe explosion-proof type intrinsically safe type:Ex d IIC T5 Gb

    QT

    other functions

     

     

    CYB03702  [102] G         U1        E1     M1                     Complete model specifications

    Ordering model CYB3702 [102] G U1 E1 G½M1 indicates that the model is CYX3702 shape product, measuring range 1MPa, gauge pressure, 24V power supply, 4~20mA output, G1/2 threaded connector, with 4-digit LCD display.

    7.3 Recommended flange size

    model

    size

    range

    DN50

    K=110   D=140   C=14

    0.6 MPa

    DN50

    K=125   D=160   C=18

    ≥1.0 MPa

    DN25

    K=75    D=100   C=12

    0.6 MPa

    DN25

    K=85    D=115   C=16

    ≥1.0 MPa

    Flange size can also be customized according to needs

     

    8 Precautions

    8.1 The flange of CYB3702 and CYB373 products can be customized, and the flange size shall be specified when ordering.

    8.2 When selecting anticorrosive CYB3704 products, pay attention to the compatibility of shell material and measuring medium.

    8.3 When the product has the risk of being soaked or submerged, it must be explained when ordering.

    8.4 When selecting strong corrosion protection products, the product shell and meter head shall be well protected, and these parts do not have strong corrosion resistance.